H2
Argo Overheat Protection / Dry-Run Protection

H2 is displayed and the humidifier shuts down; base feels warm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Running without water, Blocked air vents, Failed thermal fuse or temperature sensor in base, Excessive scale on heater or ultrasonic transducer

How to Fix / Troubleshooting

Safety: Unplug the humidifier and allow it to cool completely before servicing. Do not operate without water.

Steps:

  • Check water level: Ensure the tank is full and properly seated.
  • Clean base: Remove the tank and inspect the base for heavy scale or deposits on the heating element or ultrasonic transducer. Clean with a vinegar solution as recommended by Argo.
  • Inspect vents: Make sure air intake and exhaust vents are not blocked by dust or objects.
  • Thermal sensor check: If H2 recurs quickly, inspect the base temperature sensor or thermal fuse. Replace the Argo humidifier base temperature sensor or thermal fuse if open or out of range.
  • Test: After cleaning and part replacement, refill with water, restore power, and verify that H2 no longer appears.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Argo Humidifier Base Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements