Ebac
Short Cycling / Overheat or Protection Trip
Dehumidifier runs briefly then shuts off, tank not full
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked air filter or grille, Overheating compressor, Faulty overload protector, High ambient temperature beyond spec
How to Fix / Troubleshooting
Safety: Unplug the unit and allow it to cool before inspection.
Steps:
- 1. Clean filter and grilles: Remove and wash the air filter. Vacuum dust from intake and outlet grilles.
- 2. Check condenser coil: Access and clean the warm condenser coil. Ensure the fan is blowing strongly across it.
- 3. Ambient temperature: Verify the room is not excessively hot (above the unit's rated maximum). High temperatures can cause the compressor overload to trip.
- 4. Overload protector: Inspect the compressor overload device for signs of overheating. Replace if it trips at normal operating conditions.
- 5. Monitor operation: After cleaning and any part replacement, run the unit and observe whether it maintains operation without frequent shutdowns.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Compressor Overload Protector
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements