Ebac
No Power / Input Power Failure
Dehumidifier will not power on at all (no lights, no display)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown mains fuse on PCB, Faulty power cord, Tripped circuit breaker, Failed main control PCB power supply section
How to Fix / Troubleshooting
Safety: Ensure the unit is unplugged before opening. Mains voltage is present inside; only proceed if you are competent with electrical safety.
Steps:
- 1. External checks: Verify the wall outlet with another appliance. Check the house breaker or fuse. Inspect the Ebac power cord for cuts or burn marks.
- 2. Check onboard fuse: Remove the cover and locate the fuse on the main PCB (often a glass or ceramic fuse). Test with a multimeter and replace with the same rating if blown.
- 3. Inspect for damage: Look for burnt components or tracks on the PCB, especially near the power input and transformer or SMPS section.
- 4. Test power switch: If your model has a mechanical power switch, test it for continuity when ON. Replace if faulty.
- 5. Replace PCB: If the fuse blows again immediately or the low-voltage supply is dead, the main control PCB likely needs replacement.
Warning: Do not bypass fuses or use higher-rated fuses; this is a fire hazard.