E4
Ebac
High Temperature / Overheat Protection Fault
E4 error, compressor does not start or stops quickly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked air intake or outlet grille, Failed high-limit thermostat on compressor discharge, Overheated compressor due to dirty condenser, Faulty high-temperature sensor or wiring
How to Fix / Troubleshooting
Safety: Unplug the unit and allow it to cool for at least 20 minutes before working near the compressor or coils.
Steps:
- 1. Check airflow: Inspect the front and rear grilles. Remove any obstructions and vacuum dust from the intake and outlet. Ensure the unit is at least 30 cm from walls or furniture.
- 2. Clean condenser coil: Remove the rear or side panel to access the warm condenser coil. Use a soft brush and vacuum to remove lint and dust. Do not bend the fins.
- 3. Inspect high-limit thermostat: Many Ebac units have a thermal cut-out or thermostat clipped to the compressor discharge line. Check that it is firmly attached and that its wires are intact and connected to the PCB.
- 4. Test continuity: With power disconnected, test the high-limit thermostat with a multimeter. It should show continuity at room temperature. If it is open and does not reset after cooling, replace it.
- 5. Check fan operation: Restore power briefly and confirm that the fan runs at full speed when the compressor is commanded on. A weak or non-running fan can cause overheating.
- 6. Replace faulty parts: Replace a defective high-limit thermostat, fan motor, or temperature sensor as indicated by testing. If the compressor itself is overheating due to internal failure, a refrigeration technician is required.
Warning: Do not bypass or short the high-limit thermostat; it is a critical safety device.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
High-Limit Thermostat