P2
Ebac Condensate Pump Fault

P2 code, continuous pump models – pump not operating, water backing up

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed internal condensate pump, Blocked pump inlet or outlet hose, Stuck pump float, Pump wiring or connector fault

How to Fix / Troubleshooting

Safety: Unplug the unit. Water and electricity are present; keep connections dry.

Steps:

  • 1. Inspect hoses: Check the pump outlet hose for kinks, clogs, or freezing (if in a cold area). Clear any blockage and ensure the hose slopes downward without loops.
  • 2. Check pump reservoir: Access the internal pump tray and remove any slime, scale, or debris that may block the inlet or jam the float.
  • 3. Float movement: Manually move the pump float up and down. It should move freely and activate the pump switch. Clean and free it if stuck.
  • 4. Power test: With the unit reassembled enough to run and using caution, fill the pump tray with water and see if the pump activates. If not, check for voltage at the pump motor when the float is raised.
  • 5. Replace pump: If voltage is present but the pump does not run, replace the condensate pump assembly with the correct Ebac part.

Warning: Do not operate the unit with a known faulty pump; water damage may result.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condensate Pump Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements