Ebac
Compressor Not Starting
Unit powers on but compressor never starts, fan runs continuously
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty compressor relay on PCB, Failed compressor start capacitor (if fitted), Open compressor winding, Low ambient temperature lockout
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing internal components. Compressor circuits carry mains voltage.
Steps:
- 1. Check settings: Ensure the humidity setpoint is below the room humidity and that the unit is not in fan-only mode.
- 2. Ambient temperature: Confirm the room is within the operating temperature range; some Ebac models inhibit compressor operation at low temperatures.
- 3. Listen for relay click: When the unit calls for dehumidification, listen for a click from the compressor relay on the PCB. No click may indicate a control issue.
- 4. Inspect relay and capacitor: Access the main PCB and compressor compartment. Check the compressor relay for burn marks and test the start capacitor (if present) with a capacitance meter. Replace any faulty components.
- 5. Test compressor windings: With power off and wires removed, measure resistance between compressor terminals. Open or shorted windings indicate a failed compressor requiring professional replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor Relay / Start Capacitor
Check Price on Amazon