Frigidaire
False Bucket Full Detection
Dehumidifier shuts off and displays that the bucket is full even when the bucket is empty and properly installed.
Advertisements
Possible Causes
Stuck or misaligned bucket float, Faulty bucket full switch, Warped bucket not engaging switch, Loose wiring to bucket switch
How to Fix / Troubleshooting
Safety: Unplug the unit before working near switches.
Steps:
- Inspect float: Remove the bucket and check the float mechanism. Ensure it moves freely and is not stuck in the up position.
- Check bucket shape: Look for warping or damage that prevents the bucket from fully seating. Replace if deformed.
- Test switch manually: Locate the bucket full switch in the cabinet. Press it with your finger; you should hear a click. If not, the switch may be defective.
- Check wiring: Ensure the switch wires are firmly connected and not broken.
- Replace switch: If the switch does not change state when pressed (tested with a meter if available), replace it with a Frigidaire bucket switch.