Frigidaire

Frigidaire Humidifiers & Dehumidifiers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
CF
Dehumidifier displays CF after extended use; unit may still run.
Filter Cleaning Reminder
E1
Dehumidifier displays E1 and will not run or shuts down shortly after starting.
Room Temperature Sensor (Thermistor) Failure
E2
Dehumidifier shows E2 and stops operating or cycles off quickly.
Evaporator Coil Temperature Sensor Failure
E3
Dehumidifier displays E3 and will not dehumidify properly.
Humidity Sensor Failure / Humidity Feedback Error
E4
Dehumidifier shows E4 and shuts down or fails to start the compressor.
Defrost Sensor / Coil Temperature Protection Error
E5
Dehumidifier displays E5 and stops or will not start the compressor.
Compressor Overload / High Temperature Protection Error
EC
Dehumidifier displays EC and stops removing moisture; fan may still run but compressor does not start.
Refrigerant System / Sensor Communication Error
F0
Dehumidifier displays F0 and will not operate normally.
General Sensor / Communication Fault
F1
Dehumidifier shows F1 and does not respond to humidity settings properly.
Humidity Sensor Circuit Error
F2
Dehumidifier displays F2 and may shut down or fail to start the compressor.
Temperature Sensor Circuit Error
FL
Dehumidifier displays FL and stops running; water bucket is full or appears full to the unit.
Full Bucket Detection
HI
Dehumidifier displays HI and may run continuously or not respond to humidity setpoint.
High Humidity Indication / Sensor Out-of-Range
LO
Dehumidifier displays LO and does not start dehumidifying; may run fan only.
Low Ambient Temperature Protection
P1
Dehumidifier shows P1 and does not start dehumidifying; fan may run briefly.
Defrost Mode / Coil Protection Active
P2
Dehumidifier displays P2 and stops running; bucket may be full or appear empty depending on model.
Bucket Full / Drain System Protection
PF
Dehumidifier displays PF and stops; may occur after a power outage or surge.
Power Failure / Voltage Interruption
Symptom
Dehumidifier display and buttons work, but unit does not respond to changes in humidity setting (runs constantly or not at all).
Humidity Control Failure
Symptom
Dehumidifier display is dim, flickering, or segments are missing, but the unit may still run.
Display / User Interface Failure
Symptom
Dehumidifier emits a burning or electrical smell during operation.
Overheating Electrical Component
Symptom
Dehumidifier fan does not run; compressor may start and quickly shut down or unit shows error codes related to overheating.
Fan Motor Failure / Airflow Loss
Symptom
Dehumidifier frequently trips the household circuit breaker or blows fuses.
Excessive Current Draw / Electrical Short
Symptom
Dehumidifier has a musty or moldy odor from the air outlet.
Biological Growth in Water Path
Symptom
Dehumidifier ices up; evaporator coil covered in thick ice and airflow is reduced.
Evaporator Coil Icing / Defrost Failure
Symptom
Dehumidifier leaks water onto the floor instead of into the bucket or drain hose.
Water Leak / Drainage Failure
Symptom
Dehumidifier makes loud rattling or vibrating noises during operation.
Excessive Vibration / Loose Components
Symptom
Dehumidifier operates but causes noticeable radio or TV interference nearby.
Electromagnetic Interference (EMI)
Symptom
Dehumidifier powers on but compressor never starts; fan runs continuously and no water is collected.
Compressor Start Failure
Symptom
Dehumidifier runs briefly then shuts off; may restart after a few minutes and repeat the cycle.
Short Cycling / Overheat or Protection Trip
Symptom
Dehumidifier runs but airflow from the front grille is weak.
Restricted Airflow
Symptom
Dehumidifier runs but does not collect water; bucket remains dry even in humid conditions.
No Dehumidification / Sealed System or Airflow Failure
Symptom
Dehumidifier shuts off and displays that the bucket is full even when the bucket is empty and properly installed.
False Bucket Full Detection
Symptom
Dehumidifier turns on by itself or changes settings without input.
Control Logic / Keypad Malfunction
Symptom
Dehumidifier will not power on at all; no lights or display.
No Power / Dead Control
Symptom
Dehumidifier’s continuous drain feature does not work; water still fills the bucket.
Continuous Drain Failure
Symptom
Dehumidifier’s humidistat reading is inaccurate compared to other hygrometers.
Humidity Calibration Drift