HI
Frigidaire High Humidity Indication / Sensor Out-of-Range

Dehumidifier displays HI and may run continuously or not respond to humidity setpoint.

Advertisements

Possible Causes

Actual room humidity above sensor range, Faulty humidity sensor reading maximum value, Sensor blocked by dust or moisture, Control board misreading sensor

How to Fix / Troubleshooting

Steps:

  • Verify humidity: Use a separate hygrometer to check actual room humidity. If it is extremely high (e.g., >90%), HI may be normal until humidity drops.
  • Improve ventilation: Reduce moisture sources (drying clothes, open water containers) and increase air circulation in the room.
  • Clean sensor area: Remove and clean the air filter. Vacuum the intake grille and gently clean around the humidity sensor.
  • Power reset: Unplug for 5 minutes, then plug back in and set a target humidity (e.g., 50%).
  • Sensor replacement: If HI remains even in a dry room, the humidity sensor may be defective and should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Humidity Sensor
Check Price on Amazon