P1
Frigidaire Defrost Mode / Coil Protection Active

Dehumidifier shows P1 and does not start dehumidifying; fan may run briefly.

Advertisements

Possible Causes

Evaporator coil temperature too low, Unit operating in a cold room, Frost buildup on evaporator, Faulty defrost sensor or control logic

How to Fix / Troubleshooting

Note: On many Frigidaire dehumidifiers, P1 is not a fault but an indication that the unit is in defrost mode.

Steps:

  • Check room temperature: Ensure the room is above the minimum operating temperature (typically 41°F / 5°C). If the room is too cold, move the unit to a warmer area.
  • Allow defrost cycle: Leave the unit plugged in and powered on. P1 may clear automatically after 10–30 minutes once the coil warms up.
  • Inspect for icing: If you can see the evaporator coil, check for heavy frost or ice. If iced, turn the unit off and unplug it. Allow all ice to melt completely.
  • Clean filter and coil: A dirty filter or coil can cause low coil temperature and icing. Clean the filter and gently vacuum the coil fins.
  • Restart: After thawing and cleaning, plug in and restart. If P1 persists in a warm room with no ice, the defrost sensor or control board may be malfunctioning.
  • Service: Persistent P1 in proper conditions warrants inspection of the defrost sensor and main control board by a technician.