LO
Frigidaire Low Ambient Temperature Protection

Dehumidifier displays LO and does not start dehumidifying; may run fan only.

Advertisements

Possible Causes

Room temperature below operating range, Faulty ambient temperature sensor reading too low, Unit placed near cold draft or exterior wall, Control board miscalibration

How to Fix / Troubleshooting

Note: LO is often informational, indicating the room is too cold for safe operation.

Steps:

  • Check room temperature: Use a separate thermometer to verify the room is above 41°F / 5°C. If not, move the unit to a warmer area.
  • Avoid cold drafts: Do not place the unit directly on a cold concrete floor or next to an exterior door or window where cold air can affect the sensor.
  • Power reset: Unplug for 5 minutes, then plug back in and check if LO clears in a warmer environment.
  • Sensor check: If the room is clearly warm (e.g., 70°F / 21°C) but LO remains, inspect the ambient temperature sensor and its wiring for damage or dislodging.
  • Replace sensor if needed: A faulty ambient thermistor can falsely report low temperature and should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ambient Temperature Sensor (Thermistor)
Check Price on Amazon

We may earn a commission from links on this page.