Gree
Evaporator Coil Icing
Dehumidifier freezes up; evaporator coil becomes covered in ice during operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Room temperature too low, Restricted airflow from dirty filter or coil, Low refrigerant charge, Faulty defrost sensor or control
How to Fix / Troubleshooting
Safety: Unplug the unit and allow all ice to melt before further inspection.
Steps:
- Room temperature: Ensure the room is above the minimum operating temperature. Move to a warmer area if necessary.
- Airflow: Clean the air filter and coils to restore proper airflow.
- Defrost sensor: Check that the defrost/coil sensor is attached correctly and replace if faulty.
- Refrigerant: If icing persists despite good airflow and sensors, a refrigerant issue may exist and should be checked by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Defrost Temperature Sensor (NTC)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements