Gree

Gree Humidifiers & Dehumidifiers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
CF
Display shows CF after a certain number of operating hours; unit may still run.
Filter Cleaning Reminder
E1
Dehumidifier stops and displays E1 on the control panel; buttons may not respond or unit may not start.
Room Temperature Sensor (NTC) Failure or Open Circuit
E2
Dehumidifier displays E2 and will not run or shuts down shortly after starting.
Evaporator Coil Temperature Sensor (Pipe Sensor) Failure
E3
Dehumidifier shows E3 and compressor does not start or stops quickly.
Humidity Sensor (RH Sensor) Failure or Out of Range
E4
Dehumidifier displays E4 and stops operating; fan may run briefly then shut off.
Defrost Sensor or Anti-Frost Protection Fault
E5
Dehumidifier shows E5 and compressor does not run; fan may still operate.
Compressor Overload or High-Temperature Protection
E6
Dehumidifier displays E6 and will not start or stops unexpectedly.
Communication Error Between Display Board and Main Control Board
E7
Dehumidifier shows E7 and stops; sometimes occurs when the water tank is inserted or removed.
Water Tank Level Sensor or Float Switch Fault
E8
Dehumidifier displays E8 and shuts down; may be accompanied by unusually hot air from the outlet.
High-Temperature Protection or Overheat Fault
E9
Dehumidifier shows E9 and will not start; sometimes occurs after a power surge.
EEPROM or Memory Error on Main Control Board
EC
Dehumidifier shows EC and stops; may restart and stop repeatedly.
Refrigerant Leakage or System Protection Error
F0
Dehumidifier displays F0 and does not dehumidify; fan may still run.
Refrigerant System Low Pressure or Sensor Fault
F1
Dehumidifier shows F1 and stops; may occur intermittently during operation.
Indoor Coil Sensor or Ambient Sensor Abnormality (Model-Dependent)
F2
Dehumidifier displays F2 and will not run; sometimes appears after long continuous operation.
Full Tank or Drainage System Fault (Model-Dependent Code Mapping)
H1
Dehumidifier shows H1 and does not start dehumidifying.
High Humidity Sensor Reading or Sensor Short
H2
Dehumidifier displays H2 and may shut down or fail to start.
Low Humidity Sensor Reading or Sensor Open
HI
Display shows HI and humidity cannot be adjusted; unit may run continuously.
High Ambient Temperature or High Humidity Indication
LO
Display shows LO and dehumidifier does not start or runs only briefly.
Low Ambient Temperature Lockout
P1
Dehumidifier shows P1 and stops; water tank is full or nearly full.
Water Tank Full Protection Activated
P2
Dehumidifier displays P2 and stops; unit may be in defrost or protection mode.
Defrost Mode or Low-Temperature Protection Indication
Symptom
Buttons on the control panel do not respond or respond intermittently.
Unresponsive Control Panel / Keypad Failure
Symptom
Dehumidifier does not power on at all; no lights or display, even when plugged in.
No Power / Dead Unit
Symptom
Dehumidifier emits a burning smell or visible smoke.
Electrical Overheating / Component Burnout
Symptom
Dehumidifier fan does not run; compressor may start and then shut down quickly.
Fan Motor Failure
Symptom
Dehumidifier freezes up; evaporator coil becomes covered in ice during operation.
Evaporator Coil Icing
Symptom
Dehumidifier leaks water onto the floor instead of into the tank or drain hose.
Water Leakage / Drainage Fault
Symptom
Dehumidifier makes loud rattling or buzzing noises during operation.
Excessive Noise / Vibration
Symptom
Dehumidifier runs but collects very little or no water even in humid conditions.
Poor Dehumidification / Low Capacity
Symptom
Dehumidifier runs continuously and never reaches the set humidity level.
Inadequate Dehumidification / Oversized Space
Symptom
Dehumidifier runs for a few minutes then shuts off, even though the room is still humid and the tank is not full.
Short Cycling / Premature Shutdown
Symptom
Display is blank or very dim, but the unit may still run when plugged in.
Display Failure
Symptom
Musty or moldy odor coming from the dehumidifier during operation.
Odor / Biological Growth in Drain System
Symptom
Unit powers on but compressor never starts; fan runs continuously and no water is collected.
Compressor Not Starting
Symptom
Unit shuts off and will not restart for several minutes even when humidity is high.
Compressor Short-Cycle Protection / Thermal Delay
Symptom
Unit trips the household circuit breaker or GFCI when turned on.
Electrical Short or Ground Fault
Symptom
Unit vibrates excessively and may move on the floor during operation.
Severe Vibration
Symptom
Water tank fills too quickly or overflows even with continuous drain hose attached.
Continuous Drain Malfunction
Symptom
Water tank full indicator stays on even when the tank is empty and correctly installed.
False Tank Full Indication