F2
Gree Full Tank or Drainage System Fault (Model-Dependent Code Mapping)

Dehumidifier displays F2 and will not run; sometimes appears after long continuous operation.

Advertisements

Possible Causes

Faulty tank full switch, Blocked drain hose causing backup, Misaligned tank, Defective main PCB tank input circuit

How to Fix / Troubleshooting

Safety: Unplug the unit and remove the water tank.

Steps:

  • Empty and reseat tank: Completely empty the tank, clean it, and reinstall it firmly.
  • Check continuous drain: If using a hose, ensure it slopes downward with no kinks and that the outlet is not submerged or blocked.
  • Float switch test: Access the float switch assembly and test it with a multimeter for proper open/closed operation as the float moves.
  • Replace faulty parts: Install a new tank float switch assembly if the existing one fails continuity tests.
  • Control board: If the switch is good but F2 remains, the main control board may be misreading the tank status.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Tank Full Switch
Check Price on Amazon

We may earn a commission from links on this page.