F2
Gree
Full Tank or Drainage System Fault (Model-Dependent Code Mapping)
Dehumidifier displays F2 and will not run; sometimes appears after long continuous operation.
Advertisements
Possible Causes
Faulty tank full switch, Blocked drain hose causing backup, Misaligned tank, Defective main PCB tank input circuit
How to Fix / Troubleshooting
Safety: Unplug the unit and remove the water tank.
Steps:
- Empty and reseat tank: Completely empty the tank, clean it, and reinstall it firmly.
- Check continuous drain: If using a hose, ensure it slopes downward with no kinks and that the outlet is not submerged or blocked.
- Float switch test: Access the float switch assembly and test it with a multimeter for proper open/closed operation as the float moves.
- Replace faulty parts: Install a new tank float switch assembly if the existing one fails continuity tests.
- Control board: If the switch is good but F2 remains, the main control board may be misreading the tank status.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Tank Full Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements