P2
Gree Defrost Mode or Low-Temperature Protection Indication

Dehumidifier displays P2 and stops; unit may be in defrost or protection mode.

Advertisements

Possible Causes

Evaporator coil temperature below safe threshold, Room temperature too low, Defrost sensor misreading, Restricted airflow causing coil icing

How to Fix / Troubleshooting

Safety: Unplug the unit if there is visible ice buildup.

Steps:

  • Check room temperature: Ensure the room is within the operating range (typically above 5°C/41°F). Move the unit to a warmer area if needed.
  • Inspect for ice: Remove the front cover and look at the evaporator coil. If iced over, allow it to thaw completely before restarting.
  • Clean filter and coil: Wash the air filter and gently clean dust from the evaporator coil to improve airflow.
  • Sensor check: Verify the defrost/coil sensor is firmly attached and wiring is intact. Replace the defrost sensor if readings are abnormal.
  • Operation: After thawing and cleaning, plug in and allow the unit to run. P2 may clear automatically once coil temperature normalizes.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Defrost Temperature Sensor (NTC)
Check Price on Amazon