E8
AGLUCKY Water Pump Circuit Fault

E8 error; water pump may not run, or unit beeps with no water circulation; no ice production.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed circulation water pump, Blocked water pump inlet, Airlock in pump, Loose or damaged pump wiring

How to Fix / Troubleshooting

Safety first: Unplug the ice maker and empty the reservoir before removing the pump.

Check for simple blockages:

  • Remove the ice basket and inspect the water pump intake screen at the bottom of the reservoir. Clean any debris, scale, or slime with a soft brush and mild detergent, then rinse thoroughly.
  • Refill with clean water and restart. Listen for the pump running (a soft humming sound) and watch for water flowing over the evaporator grid.

Bleed air from the pump:

  • If the pump is humming but not moving water, tilt the unit slightly forward and backward a few times (while off) to help release trapped air, then restart.

Inspect pump and wiring:

  • Unplug again. Access the circulation pump from the bottom or side panel.
  • Check that the pump connector is firmly attached to the control board and that wires are intact.
  • Remove the pump and inspect the impeller for obstructions or damage.

Next steps:

  • If the pump does not run at all when powered, replace it with a compatible AGLUCKY water circulation pump.
  • If a new pump does not resolve E8, the control board pump driver circuit may be faulty and require replacement.