E8
Amica
Water Overflow Protection Error
E8 appears and the unit beeps; water overflows into the bin or internal sump level is too high.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck water inlet valve, Faulty water level sensor, Blocked overflow channel, Control PCB not closing inlet valve
How to Fix / Troubleshooting
Safety first: Unplug the unit and close the water supply immediately to prevent flooding.
- Drain excess water: Remove the ice bin and manually scoop or sponge out excess water from the sump and bin area.
- Inspect water level sensor: Locate the float or electronic level sensor in the sump. Check for mineral deposits or debris that may prevent proper movement or sensing. Clean with warm water and a soft brush.
- Check overflow path: Ensure the overflow channel or hose is not blocked by scale or foreign objects. Flush with warm water.
- Test inlet valve: With the unit unplugged, disconnect the water inlet hose and check for continuous dripping from the valve outlet. If water flows even with no power, the valve is stuck open and must be replaced.
- Monitor refill: After reassembly, restore water and power, then observe a fill cycle. If the water continues to rise beyond the normal level, shut off the water and have the control PCB inspected or replaced by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Water Inlet Valve Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements