Ice Thickness Sensor / Probe Fault
E10 error appears, ice cubes are irregular in size or the harvest cycle fails.
Advertisements
Possible Causes
Misadjusted ice thickness probe, Scale buildup on thickness sensor, Failed thickness sensor switch, Broken sensor bracket
How to Fix / Troubleshooting
Safety: Disconnect power before adjusting or cleaning sensors.
- Locate the thickness sensor: On many Baridi ice makers, a metal or plastic probe sits near the evaporator to detect ice thickness before harvest.
- Clean the probe: Mineral deposits can insulate the probe. Wipe it with a cloth soaked in white vinegar, then rinse with clean water and dry.
- Check alignment and gap: Ensure the probe is positioned according to the user manual (typically a few millimeters from the evaporator surface). Gently bend or adjust the bracket if it has been knocked out of place.
- Inspect the switch or sensor body: Make sure the sensor housing is not cracked and that its wiring is intact. Reseat the connector on the control PCB.
- Test operation: After cleaning and adjustment, run a cycle and observe whether the machine now harvests at the correct ice thickness. If E10 returns, replace the ice thickness sensor assembly.