L1
Baridi Low Temperature / Sensor Calibration Fault

L1 or LO displayed, unit indicates low temperature or sensor reading error; ice may be too thick or machine may shut down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Evaporator sensor out of calibration, Sensor shorted, Control board misreading sensor, Ice buildup around sensor

How to Fix / Troubleshooting

Safety: Disconnect power before working inside the cabinet.

  • Defrost ice buildup: If there is heavy ice accumulation around the evaporator and sensor, turn the unit off, remove the basket, and allow it to fully defrost. Use towels to catch meltwater.
  • Inspect sensor placement: Ensure the evaporator NTC sensor is correctly attached and not embedded in thick ice or insulation.
  • Check sensor wiring: Look for damaged insulation or crushed wires between the sensor and control board.
  • Test sensor resistance: Measure the NTC sensor resistance at room temperature and compare to Baridi’s spec. Replace if readings are out of range.
  • Control board: If a new sensor does not resolve L1, the control PCB may be misinterpreting the signal and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator NTC Temperature Sensor
Check Price on Amazon