Possible Causes

Excessive water fill, Ice thickness sensor misadjusted, Ice bin not being emptied regularly, Warm air infiltration causing partial melt and refreeze

How to Fix / Troubleshooting

Safety first: Unplug the unit before adjusting internal controls.

Steps:

  • 1. Adjust ice thickness: If your Blomberg model allows, reduce the ice thickness or fill time setting according to the manual.
  • 2. Improve door seal: Inspect the bin door gasket for gaps or damage. Replace if warm air is leaking in.
  • 3. Empty bin regularly: Use ice frequently or store excess in a freezer to prevent long-term clumping.
  • 4. Check level sensor: Ensure the ice level sensor is not obstructed and correctly detects a full bin to stop production.