E6
Bomann
Ice Basket Position / Removal Detection Fault
Display shows E6, machine beeps and stops, ice basket may be out of position.
Advertisements
Possible Causes
Ice basket not seated correctly, Faulty basket presence switch, Broken basket guide or tab, Loose wiring to basket sensor
How to Fix / Troubleshooting
Safety first: Disconnect power before manipulating internal plastic parts to avoid accidental motor movement.
Steps:
- Re-seat the ice basket: Remove the basket completely and check for broken tabs or deformed edges. Reinsert it fully so it sits flat and engages any rear or side guides.
- Check for obstructions: Make sure no ice cubes or foreign objects are trapped under or behind the basket, preventing it from sitting correctly.
- Inspect basket switch: Some Bomann models use a small microswitch or magnetic sensor to detect the basket. Look for a small lever or magnet area where the basket meets the housing. Clean it gently and ensure it is not bent.
- Restart: Plug the unit back in and start a cycle. If E6 persists with the basket correctly installed, the switch or sensor may be defective.
Service note: Replacing the basket presence switch or reed sensor requires opening the cabinet and should be done by a technician.