E16
Brandt Ice Thickness Sensor / Probe Fault

E16 displayed, ice cubes are irregularly shaped or very thin, cycle times are abnormal.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Misadjusted ice thickness probe, Scale buildup on thickness sensor, Broken or corroded thickness probe wiring, Failed ice thickness control circuit on PCB

How to Fix / Troubleshooting

Safety first: Disconnect power and water before adjusting or cleaning the ice thickness sensor.

  • Locate thickness probe: On many Brandt ice makers, a metal or plastic probe contacts the ice slab to determine thickness. Access it near the evaporator plate.
  • Clean the probe: Remove mineral deposits with a soft cloth and a mild descaling solution. Rinse and dry thoroughly.
  • Check adjustment: Follow the Brandt service manual to set the correct gap or position of the probe relative to the evaporator plate. Incorrect adjustment can cause thin or thick ice.
  • Inspect wiring: Ensure the probe's harness is intact and firmly connected to the main PCB. Repair or replace damaged wiring.
  • Test operation: Restore power and run a cycle. If E16 persists and ice thickness remains incorrect, replace the ice thickness sensor or the main control board if the sensor tests good.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ice Thickness Sensor / Probe
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements