E9
Brandt
Low Water Flow / Water Level Detection Fault
E9 error appears, ice cubes are very small or hollow, unit may stop mid-cycle.
Advertisements
Possible Causes
Partially clogged water distribution tube, Scale buildup in water trough, Faulty water level sensor or float switch, Incorrect installation causing siphoning or drain back
How to Fix / Troubleshooting
Safety first: Disconnect power and close the water supply before internal cleaning.
- Clean water system: Remove the ice bin and access the water trough and distribution tube. Use a food-safe descaler or white vinegar solution to dissolve mineral deposits. Rinse thoroughly.
- Inspect float or level sensor: If your Brandt model uses a float, ensure it moves freely and is not obstructed by scale or debris. For electronic level sensors, clean the probes and check wiring.
- Check for siphoning: Ensure the drain hose is routed according to the installation manual, with no low loops that could cause water to siphon out of the trough.
- Run a test cycle: Restore water and power, then observe the fill level. If the trough does not reach the proper level and E9 recurs, replace the water level sensor or float switch assembly.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Level Sensor / Float Switch
Check Price on Amazon
We may earn a commission from links on this page.