Brandt Cloudy Ice / Entrained Air and Minerals

Ice cubes are cloudy or white instead of clear.

Advertisements

Possible Causes

High mineral content in water, Insufficient purge during freeze cycle, Scale on evaporator surface, Low water temperature entering unit

How to Fix / Troubleshooting

Safety first: Disconnect power and water before internal cleaning.

  • Descale evaporator: Clean the evaporator plate with a descaling solution to improve surface condition and freezing pattern.
  • Improve water quality: Install or replace an inline water filter to reduce minerals and particulates.
  • Run cleaning cycles: Perform regular cleaning cycles as recommended by Brandt to maintain optimal ice clarity.
  • Check water temperature: Avoid connecting the ice maker to a warm water line; use cold water supply only.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Inline Water Filter
Check Price on Amazon

We may earn a commission from links on this page.