E11
Camry
Water Flow or Circulation Pump Fault
E11 error, ice cubes are misshapen or partially frozen, and cycles may abort early.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed circulation pump, Blocked water distribution tube, Scale buildup on pump impeller, Loose pump wiring connector
How to Fix / Troubleshooting
Safety first: Unplug the ice maker and drain water from the reservoir before servicing the pump.
- Inspect water distribution: Open the top cover and observe the water spraying or flowing over the evaporator (if possible). Weak or uneven flow indicates a circulation issue.
- Clean spray bar or distributor: Remove the water distribution tube or spray bar and flush it under warm water to clear mineral deposits.
- Access circulation pump: From the lower front or rear, locate the circulation pump connected to the reservoir. Remove any debris from the pump inlet screen.
- Check impeller: If accessible, inspect the impeller for scale buildup and clean gently.
- Reconnect and test: Reassemble, refill the reservoir, and run a cycle. If E11 persists and the pump does not run, replace the Camry circulation pump.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements