E1
Ice maker will not power on, display is blank or only shows E1 shortly after plugging in.
Main Control Board Communication Failure
E10
E10 displayed, unit may run but produces very little or no ice, often in a warm environment.
High Ambient Temperature or Overheat Protection
E11
E11 error, ice cubes are misshapen or partially frozen, and cycles may abort early.
Water Flow or Circulation Pump Fault
E12
E12 displayed, unit beeps and stops; often occurs when the water reservoir is empty or nearly empty.
Low Water Level Protection Fault
E13
E13 error, unit may freeze up with thick ice on the evaporator or stop mid‑cycle.
Evaporator Over‑Ice / Freeze Protection Fault
E14
E14 displayed, unit may not respond to button presses or responds erratically.
User Interface / Keypad Communication Error
E15
E15 error, unit may trip the household breaker or show signs of internal short circuit.
Internal Electrical Short or Ground Fault
E16
E16 displayed, ice production is very slow and cubes are small or hollow.
Refrigeration System Underperformance
E17
E17 error, unit may stop with water overflowing into the bin or onto the floor.
Overfill / Overflow Protection Fault
E18
E18 displayed, unit may not start a cycle and internal lights or fans may still operate.
Door / Lid Open or Safety Switch Fault
E19
E19 error, unit may freeze water but fail to release ice from the evaporator.
Harvest Motor or Ice Release Mechanism Fault
E2
Unit powers on but stops shortly after starting, beeps, and displays E2.
Water Inlet Valve or Water Level Sensor Fault
E20
E20 displayed, unit may shut down unexpectedly and restart after a power cycle.
Internal Memory or Firmware Error
E3
Camry ice maker runs briefly, then stops with E3 on the display and no ice is produced.
Evaporator Temperature Sensor (Thermistor) Fault
E4
Display shows E4 and the ice maker stops mid‑cycle, often during harvest or defrost.
Defrost / Hot Gas Valve or Sensor Error
E5
E5 appears and the unit stops; ice size is inconsistent or cycle time is abnormally long before the error.
Ice Thickness Sensor / Probe Fault
E6
E6 error code, unit may start but quickly shuts down, sometimes with a clicking sound from the compressor area.
Compressor Overload or Start Circuit Fault
E7
E7 displayed, fan noise stops or is intermittent, unit overheats and shuts down.
Condenser Fan Motor Failure
E8
E8 appears and the ice bin is empty or nearly empty; unit may beep continuously.
Ice Bin Full Sensor or Infrared Beam Fault
E9
E9 error, unit stops and may have standing water in the bottom of the ice‑making chamber.
Drain Pump or Drain Sensor Fault
Symptom
Camry ice maker does not turn on at all, no lights or display, completely dead.
No Power / Power Supply Failure
Symptom
Clicking sound and the unit repeatedly tries and fails to start cooling.
Compressor Start Failure
Symptom
Condensation or frost forming on the outside of the cabinet.
Excessive Condensation / Insulation Issue
Symptom
Display and lights work, but pressing the Start button does nothing.
Start Circuit / Keypad Input Failure
Symptom
High‑pitched squealing or grinding noise from inside the unit.
Worn Pump or Fan Bearings
Symptom
Ice cubes are too large, solid blocks, or stick together in clumps.
Excessive Ice Thickness / Slow Harvest
Symptom
Ice cubes are too small, thin, or hollow in the center.
Insufficient Water Fill or Fast Freeze
Symptom
Ice has a bad taste or odor (chemical, plastic, or musty).
Contaminated Water Path
Symptom
Ice maker leaks water onto the counter or floor during operation.
External Water Leak
Symptom
Ice maker produces ice, but output is very low compared to normal.
Reduced Ice Production
Symptom
Ice maker runs but produces no ice at all; evaporator does not get cold.
Complete Loss of Cooling
Symptom
Ice melts quickly in the bin and the bin area feels warm.
Poor Bin Insulation or Warm Air Infiltration
Symptom
Loud rattling or vibrating noise during operation.
Excessive Vibration / Loose Components
Symptom
Unit emits a burning smell during operation.
Overheating Electrical Component
Symptom
Unit frequently shuts off and restarts on its own without user input.
Intermittent Power or Overheat Cycling
Symptom
Unit is very hot to the touch on the sides or top during operation.
Overheating Cabinet
Symptom
Unit runs continuously and does not cycle off even when bin is full.
Ice Level Detection Failure
Symptom
Unit turns on and fills with water but shuts off before freezing completes.
Premature Cycle Termination
Symptom
Visible white scale or mineral buildup on the evaporator and internal surfaces.
Lime Scale / Mineral Deposits
Symptom
Water accumulates inside the ice bin or reservoir and does not drain properly.
Internal Drainage Problem
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E1 |
Ice maker will not power on, display is blank or only shows E1 shortly after plugging in.
|
Main Control Board Communication Failure | View Details |
| E10 |
E10 displayed, unit may run but produces very little or no ice, often in a warm environment.
|
High Ambient Temperature or Overheat Protection | View Details |
| E11 |
E11 error, ice cubes are misshapen or partially frozen, and cycles may abort early.
|
Water Flow or Circulation Pump Fault | View Details |
| E12 |
E12 displayed, unit beeps and stops; often occurs when the water reservoir is empty or nearly empty.
|
Low Water Level Protection Fault | View Details |
| E13 |
E13 error, unit may freeze up with thick ice on the evaporator or stop mid‑cycle.
|
Evaporator Over‑Ice / Freeze Protection Fault | View Details |
| E14 |
E14 displayed, unit may not respond to button presses or responds erratically.
|
User Interface / Keypad Communication Error | View Details |
| E15 |
E15 error, unit may trip the household breaker or show signs of internal short circuit.
|
Internal Electrical Short or Ground Fault | View Details |
| E16 |
E16 displayed, ice production is very slow and cubes are small or hollow.
|
Refrigeration System Underperformance | View Details |
| E17 |
E17 error, unit may stop with water overflowing into the bin or onto the floor.
|
Overfill / Overflow Protection Fault | View Details |
| E18 |
E18 displayed, unit may not start a cycle and internal lights or fans may still operate.
|
Door / Lid Open or Safety Switch Fault | View Details |
| E19 |
E19 error, unit may freeze water but fail to release ice from the evaporator.
|
Harvest Motor or Ice Release Mechanism Fault | View Details |
| E2 |
Unit powers on but stops shortly after starting, beeps, and displays E2.
|
Water Inlet Valve or Water Level Sensor Fault | View Details |
| E20 |
E20 displayed, unit may shut down unexpectedly and restart after a power cycle.
|
Internal Memory or Firmware Error | View Details |
| E3 |
Camry ice maker runs briefly, then stops with E3 on the display and no ice is produced.
|
Evaporator Temperature Sensor (Thermistor) Fault | View Details |
| E4 |
Display shows E4 and the ice maker stops mid‑cycle, often during harvest or defrost.
|
Defrost / Hot Gas Valve or Sensor Error | View Details |
| E5 |
E5 appears and the unit stops; ice size is inconsistent or cycle time is abnormally long before the error.
|
Ice Thickness Sensor / Probe Fault | View Details |
| E6 |
E6 error code, unit may start but quickly shuts down, sometimes with a clicking sound from the compressor area.
|
Compressor Overload or Start Circuit Fault | View Details |
| E7 |
E7 displayed, fan noise stops or is intermittent, unit overheats and shuts down.
|
Condenser Fan Motor Failure | View Details |
| E8 |
E8 appears and the ice bin is empty or nearly empty; unit may beep continuously.
|
Ice Bin Full Sensor or Infrared Beam Fault | View Details |
| E9 |
E9 error, unit stops and may have standing water in the bottom of the ice‑making chamber.
|
Drain Pump or Drain Sensor Fault | View Details |
| – |
Camry ice maker does not turn on at all, no lights or display, completely dead.
|
No Power / Power Supply Failure | View Details |
| – |
Clicking sound and the unit repeatedly tries and fails to start cooling.
|
Compressor Start Failure | View Details |
| – |
Condensation or frost forming on the outside of the cabinet.
|
Excessive Condensation / Insulation Issue | View Details |
| – |
Display and lights work, but pressing the Start button does nothing.
|
Start Circuit / Keypad Input Failure | View Details |
| – |
High‑pitched squealing or grinding noise from inside the unit.
|
Worn Pump or Fan Bearings | View Details |
| – |
Ice cubes are too large, solid blocks, or stick together in clumps.
|
Excessive Ice Thickness / Slow Harvest | View Details |
| – |
Ice cubes are too small, thin, or hollow in the center.
|
Insufficient Water Fill or Fast Freeze | View Details |
| – |
Ice has a bad taste or odor (chemical, plastic, or musty).
|
Contaminated Water Path | View Details |
| – |
Ice maker leaks water onto the counter or floor during operation.
|
External Water Leak | View Details |
| – |
Ice maker produces ice, but output is very low compared to normal.
|
Reduced Ice Production | View Details |
| – |
Ice maker runs but produces no ice at all; evaporator does not get cold.
|
Complete Loss of Cooling | View Details |
| – |
Ice melts quickly in the bin and the bin area feels warm.
|
Poor Bin Insulation or Warm Air Infiltration | View Details |
| – |
Loud rattling or vibrating noise during operation.
|
Excessive Vibration / Loose Components | View Details |
| – |
Unit emits a burning smell during operation.
|
Overheating Electrical Component | View Details |
| – |
Unit frequently shuts off and restarts on its own without user input.
|
Intermittent Power or Overheat Cycling | View Details |
| – |
Unit is very hot to the touch on the sides or top during operation.
|
Overheating Cabinet | View Details |
| – |
Unit runs continuously and does not cycle off even when bin is full.
|
Ice Level Detection Failure | View Details |
| – |
Unit turns on and fills with water but shuts off before freezing completes.
|
Premature Cycle Termination | View Details |
| – |
Visible white scale or mineral buildup on the evaporator and internal surfaces.
|
Lime Scale / Mineral Deposits | View Details |
| – |
Water accumulates inside the ice bin or reservoir and does not drain properly.
|
Internal Drainage Problem | View Details |
No matching codes found
Advertisements