E17
Camry Overfill / Overflow Protection Fault

E17 error, unit may stop with water overflowing into the bin or onto the floor.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck water inlet valve, Faulty water level sensor, Blocked overflow drain, Control board not closing inlet valve

How to Fix / Troubleshooting

Safety first: Unplug the ice maker and shut off the water supply immediately to stop overflow.

  • Clean overflow drain: Locate the overflow outlet in the reservoir and ensure it is not blocked by debris or scale.
  • Check water level sensor: Inspect the float or level probes for free movement and cleanliness. Clean as needed.
  • Test inlet valve: With water supply off, disconnect the outlet hose from the Camry inlet valve. Turn water on briefly; if water flows through the valve with no power applied, the valve is stuck open and must be replaced.
  • Inspect control wiring: Ensure the inlet valve wiring harness is intact and not shorted.

After correcting the cause, dry the interior, restore water and power, and test. Persistent E17 may indicate a control board fault.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Inlet Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements