E11
Caso
Low Refrigerant / Sealed System Performance Fault (Detected by Temperature Profile)
E11 error; fan runs but ice production is extremely slow or absent; unit may run continuously.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Refrigerant leak in evaporator or tubing, Partially blocked capillary tube, Weak compressor, Severely dirty condenser reducing heat rejection
How to Fix / Troubleshooting
Safety: Do not attempt to open the sealed refrigeration system yourself. Refrigerant handling requires certified equipment and training.
What you can do:
- Clean condenser and ensure airflow: Unplug the unit, remove the rear cover, and thoroughly clean the condenser coil and fan area. Ensure adequate ventilation around the unit.
- Check ambient temperature: Move the ice maker to a cooler room if ambient temperature is above the manufacturer's recommended range (often 10–32°C).
- Observe frost pattern: With the cover removed and the unit running, a healthy system will show even frost across most of the evaporator. A small patch of frost near the capillary inlet and warm elsewhere suggests low refrigerant or a restriction.
- Power-cycle and monitor: After cleaning and relocating, unplug for 10 minutes, then restart and monitor ice production for 1–2 hours.
- Call a professional: If E11 persists and ice production remains poor despite good airflow and ambient conditions, contact a qualified refrigeration technician. They can check system pressures, locate leaks, and recharge or repair the sealed system.
Advertisements
Repair Difficulty
Professional Required