Euhomy Condenser Fan Failure

Condenser fan does not run, but compressor becomes very hot.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed fan motor, Obstructed fan blade, Loose fan wiring connector, Faulty control board fan output

How to Fix / Troubleshooting

Safety first: Unplug the unit. The compressor and surrounding area may be hot.

Steps:

  • 1. Inspect fan area: Remove the rear/bottom panel and check for debris blocking the fan blade.
  • 2. Spin test: Try spinning the fan blade by hand. If it is stiff or seized, replace the fan motor.
  • 3. Check wiring: Ensure the fan's connector is firmly attached to the control board and wires are intact.
  • 4. Voltage test: If you have electrical skills, test for voltage at the fan connector when the unit is running. If no voltage is present, the control board may be faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements