Gram
Short Cycling / Control Instability
Ice maker frequently starts and stops; short cycling of compressor.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty temperature sensor, Incorrect ambient conditions, Control board relay fault, Overheating due to dirty condenser
How to Fix / Troubleshooting
Safety first: Disconnect power before cleaning or testing sensors.
- Clean condenser coil: Remove dust and debris from the condenser to prevent overheating and high‑pressure trips.
- Check ambient temperature: Ensure the unit is not installed in an area outside the specified temperature range.
- Test temperature sensors: Measure resistance of the evaporator and cabinet NTC sensors and compare to Gram specifications. Replace any sensor that is out of range.
- Control board inspection: If sensors and condenser are fine, the compressor relay on the PCB may be failing, causing rapid cycling. Replace the main control PCB if necessary.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Gram Evaporator NTC Sensor
Check Price on Amazon