HOMCOM Overfilling / Water Level Control Failure

Unit overflows water inside, flooding the ice-making compartment.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck water level float in low position, Shorted water level sensor, Faulty main PCB not responding to level input, Incorrectly routed or kinked overflow hose

How to Fix / Troubleshooting

Safety first: Unplug the unit immediately and mop up water. Do not operate with standing water inside.

Steps to correct overfilling:

  • 1. Inspect float movement: Remove the reservoir and verify the float moves freely from low to high positions. Clean and descale as needed.
  • 2. Test water level switch: Use a multimeter to ensure the switch changes state as the float moves. Replace if it remains stuck.
  • 3. Check overflow path: Ensure any overflow or drain hose is not blocked or kinked.
  • 4. Inspect PCB response: If the switch works but the pump continues to run and overfill, the main control board may not be reading the signal correctly and may need replacement.

Warning: Water contacting electrical parts can cause shock or fire; allow everything to dry completely before reassembly and testing.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Level Float Switch