Indesit
Display / UI Power Fault
Display is blank or very dim, but the compressor and fans still run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed display module, Loose UI connector, Faulty low-voltage supply on main board, Damaged backlight LEDs
How to Fix / Troubleshooting
Safety: Unplug the unit before removing the control panel.
- Check UI connections: Remove the front panel and reseat the ribbon cable or harness to the display.
- Inspect for damage: Look for burnt components on the UI board or main board's low-voltage section.
- Measure low-voltage output: A qualified person can check for 5V/12V outputs from the main board to the UI. If missing, replace the main control board.
- Replace display module: If voltages are correct but the display remains blank, replace the user interface/display assembly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Display Module
Check Price on Amazon