NewAir
Display Backlight / UI Power Issue
Display is blank or very dim, but the unit still runs and makes ice.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed display backlight LEDs, Loose display connector, Partial failure of UI board power circuit
How to Fix / Troubleshooting
Safety first: Unplug the unit before opening the control panel.
Steps to restore display:
- Check contrast/brightness (if available): Some models allow adjustment; verify settings in the manual.
- Inspect connectors: Reseat the display ribbon cable and check for corrosion.
- Replace UI board: If the display remains blank or unreadable, replace the user interface/display board with a NewAir-compatible part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface Board