Severin Compressor Start Circuit Failure (Silent)

Fan runs but compressor never starts; no cooling, no error code displayed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay, Open thermal overload, Weak compressor that cannot start, Faulty control PCB relay output

How to Fix / Troubleshooting

Safety first: Unplug the unit and allow it to sit for several minutes before accessing the compressor area.

  • Listen for clicks: When plugging in and starting a cycle, listen near the compressor. Repeated clicking without running indicates start circuit issues.
  • Check start relay and overload: Remove and test the relay and overload as described in the E2 section. Replace if defective.
  • Measure compressor windings: Use a multimeter to verify the compressor windings are not open or shorted.
  • Check PCB relay: With caution and proper tools, verify that the control PCB sends power to the compressor when commanded. If not, the PCB relay may be faulty.
  • Replace components: Install a new start relay/overload or main PCB as indicated by tests. If the compressor itself is defective, professional replacement is required and may not be economical.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Compressor Start Relay
Check Price on Amazon

We may earn a commission from links on this page.