E12
Siemens Defrost Heater or Defrost Control Fault

E12 displayed, unit beeps, ice melts in bin despite compressor operation

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective defrost heater element, Failed defrost thermostat or sensor, Control board defrost relay failure, Wiring issue in defrost circuit

How to Fix / Troubleshooting

Safety: Disconnect power before accessing the evaporator and heater. Components can be sharp and edges may be hot.

Defrost system checks:

  • Access evaporator: Remove the interior rear panel to expose the evaporator coil and defrost heater.
  • Inspect heater: Look for breaks or burn marks on the Siemens defrost heater. Measure continuity with a multimeter; an open circuit indicates a failed heater.
  • Check defrost thermostat: The thermostat or thermal fuse is usually clipped to the evaporator. Test for continuity when the sensor is cold (below freezing). No continuity when cold suggests replacement is needed.
  • Control board: If heater and thermostat test good, the main control PCB may not be initiating defrost. This requires further diagnosis and likely board replacement.

Note: Incorrect defrost can cause both excessive frost and warming; ensure all components are correctly reinstalled.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost Heater
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements