E01
Ice maker will not power on, display is dark, no interior lights or sounds
Main Control Board Power Supply Failure
E02
Ice maker powers on but compressor does not start, no cooling, fan may run
Compressor Start Circuit or Inverter Failure
E03
Ice maker not cooling sufficiently, ice production very slow, compartment temperature too high
Evaporator Fan or Air Circulation Failure
E04
No water entering ice maker, no ice production, water inlet symbol or E04 displayed
Water Inlet Valve Failure or Water Supply Interruption
E05
Ice maker overfills with water, water spilling into bin or freezing into a solid block
Fill Level Sensor or Inlet Valve Stuck Open
E06
Ice maker stops mid-cycle, ice partially formed, unit beeps and displays E06
Evaporator Temperature Sensor (Thermistor) Fault
E07
Ice bin full but ice maker continues to produce ice, or E07 displayed with bin removed
Ice Bin Level Sensor or Infrared Beam Failure
E08
Ice cubes are very small, hollow, or irregular; E08 water flow error may appear
Restricted Water Flow to Ice Maker
E09
Ice maker displays E09 and stops, compressor runs briefly then shuts off
Condenser Overheating or High Temperature Protection
E10
Ice maker shows E10, no ice production, but compartment is cold
Ice Ejector Motor or Harvest Mechanism Failure
E11
Display shows E11, ice production stops, interior fan may still run
Cabinet Temperature Sensor Fault
E12
E12 displayed, unit beeps, ice melts in bin despite compressor operation
Defrost Heater or Defrost Control Fault
E13
E13 error, water present in base pan, unit may stop for safety
Leak Detection or Overflow Switch Activated
E14
E14 displayed, unit does not respond to button presses or responds erratically
User Interface Panel Communication Error
E15
E15 error, ice maker stops, audible alarm may sound
Internal Communication Bus Error
E16
E16 displayed, ice maker noisy during operation, fan speed error logged
Evaporator Fan Speed or Feedback Error
E17
E17 error, ice maker stops, water-related fault indicated
Flow Meter or Water Quantity Sensor Error
E18
E18 displayed, ice maker does not drain meltwater properly, water accumulates
Drain Pump or Drain System Failure
E19
E19 error, ice maker cycles but ice quality is poor and cloudy
Water Purity or Internal Filter Fault
E20
E20 displayed, unit fails self-test at startup
General Self-Test Failure (Multiple Possible Subsystems)
Symptom
Buttons on the control panel are unresponsive or respond intermittently
User Interface Keypad Failure
Symptom
Display is blank but interior light works and unit seems to cool
Display Module or Low-Voltage Supply Failure
Symptom
Door or drawer of the ice maker does not close properly or pops open
Door Alignment or Gasket Seal Problem
Symptom
Excessive frost or ice buildup on the evaporator or interior walls
Frost Accumulation / Defrost System Issue
Symptom
Ice cubes are fused together into large clumps in the bin
Ice Clumping Due to Temperature or Harvest Issues
Symptom
Ice cubes are too large, overflowing the tray and sticking together
Overfilling of Ice Tray
Symptom
Ice cubes are too small or hollow without any error code
Underfilling of Ice Tray
Symptom
Ice maker has a strong musty or chemical odor, ice tastes bad
Odor Contamination in Water Path or Interior
Symptom
Ice maker is very noisy during operation (grinding, rattling, or buzzing)
Mechanical Noise from Fan, Compressor, or Ice Mechanism
Symptom
Ice maker leaking water onto the floor from underneath
External Water Leak
Symptom
Ice maker not producing any ice, no error code displayed, unit appears to run
General No-Ice Production Fault
Symptom
Ice maker produces ice but at a very slow rate compared to normal
Reduced Ice Production Capacity
Symptom
Ice maker runs continuously without cycling off, ice bin overfilled or very cold
Control or Thermostat Stuck On
Symptom
Ice maker trips the household circuit breaker or RCD when it starts
Electrical Short or Ground Fault
Symptom
Ice maker vibrates excessively or rattles against cabinetry
Excessive Vibration or Poor Installation
Symptom
Ice maker will not start at all, but interior light works and display is on
Control Lock, Mode Setting, or Start Inhibit
Symptom
Interior light does not turn on when door is opened
Door Switch or LED Module Failure
Symptom
Water pooling inside the ice storage bin or at the bottom of the compartment
Internal Drainage or Meltwater Management Problem
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E01 |
Ice maker will not power on, display is dark, no interior lights or sounds
|
Main Control Board Power Supply Failure | View Details |
| E02 |
Ice maker powers on but compressor does not start, no cooling, fan may run
|
Compressor Start Circuit or Inverter Failure | View Details |
| E03 |
Ice maker not cooling sufficiently, ice production very slow, compartment temperature too high
|
Evaporator Fan or Air Circulation Failure | View Details |
| E04 |
No water entering ice maker, no ice production, water inlet symbol or E04 displayed
|
Water Inlet Valve Failure or Water Supply Interruption | View Details |
| E05 |
Ice maker overfills with water, water spilling into bin or freezing into a solid block
|
Fill Level Sensor or Inlet Valve Stuck Open | View Details |
| E06 |
Ice maker stops mid-cycle, ice partially formed, unit beeps and displays E06
|
Evaporator Temperature Sensor (Thermistor) Fault | View Details |
| E07 |
Ice bin full but ice maker continues to produce ice, or E07 displayed with bin removed
|
Ice Bin Level Sensor or Infrared Beam Failure | View Details |
| E08 |
Ice cubes are very small, hollow, or irregular; E08 water flow error may appear
|
Restricted Water Flow to Ice Maker | View Details |
| E09 |
Ice maker displays E09 and stops, compressor runs briefly then shuts off
|
Condenser Overheating or High Temperature Protection | View Details |
| E10 |
Ice maker shows E10, no ice production, but compartment is cold
|
Ice Ejector Motor or Harvest Mechanism Failure | View Details |
| E11 |
Display shows E11, ice production stops, interior fan may still run
|
Cabinet Temperature Sensor Fault | View Details |
| E12 |
E12 displayed, unit beeps, ice melts in bin despite compressor operation
|
Defrost Heater or Defrost Control Fault | View Details |
| E13 |
E13 error, water present in base pan, unit may stop for safety
|
Leak Detection or Overflow Switch Activated | View Details |
| E14 |
E14 displayed, unit does not respond to button presses or responds erratically
|
User Interface Panel Communication Error | View Details |
| E15 |
E15 error, ice maker stops, audible alarm may sound
|
Internal Communication Bus Error | View Details |
| E16 |
E16 displayed, ice maker noisy during operation, fan speed error logged
|
Evaporator Fan Speed or Feedback Error | View Details |
| E17 |
E17 error, ice maker stops, water-related fault indicated
|
Flow Meter or Water Quantity Sensor Error | View Details |
| E18 |
E18 displayed, ice maker does not drain meltwater properly, water accumulates
|
Drain Pump or Drain System Failure | View Details |
| E19 |
E19 error, ice maker cycles but ice quality is poor and cloudy
|
Water Purity or Internal Filter Fault | View Details |
| E20 |
E20 displayed, unit fails self-test at startup
|
General Self-Test Failure (Multiple Possible Subsystems) | View Details |
| – |
Buttons on the control panel are unresponsive or respond intermittently
|
User Interface Keypad Failure | View Details |
| – |
Display is blank but interior light works and unit seems to cool
|
Display Module or Low-Voltage Supply Failure | View Details |
| – |
Door or drawer of the ice maker does not close properly or pops open
|
Door Alignment or Gasket Seal Problem | View Details |
| – |
Excessive frost or ice buildup on the evaporator or interior walls
|
Frost Accumulation / Defrost System Issue | View Details |
| – |
Ice cubes are fused together into large clumps in the bin
|
Ice Clumping Due to Temperature or Harvest Issues | View Details |
| – |
Ice cubes are too large, overflowing the tray and sticking together
|
Overfilling of Ice Tray | View Details |
| – |
Ice cubes are too small or hollow without any error code
|
Underfilling of Ice Tray | View Details |
| – |
Ice maker has a strong musty or chemical odor, ice tastes bad
|
Odor Contamination in Water Path or Interior | View Details |
| – |
Ice maker is very noisy during operation (grinding, rattling, or buzzing)
|
Mechanical Noise from Fan, Compressor, or Ice Mechanism | View Details |
| – |
Ice maker leaking water onto the floor from underneath
|
External Water Leak | View Details |
| – |
Ice maker not producing any ice, no error code displayed, unit appears to run
|
General No-Ice Production Fault | View Details |
| – |
Ice maker produces ice but at a very slow rate compared to normal
|
Reduced Ice Production Capacity | View Details |
| – |
Ice maker runs continuously without cycling off, ice bin overfilled or very cold
|
Control or Thermostat Stuck On | View Details |
| – |
Ice maker trips the household circuit breaker or RCD when it starts
|
Electrical Short or Ground Fault | View Details |
| – |
Ice maker vibrates excessively or rattles against cabinetry
|
Excessive Vibration or Poor Installation | View Details |
| – |
Ice maker will not start at all, but interior light works and display is on
|
Control Lock, Mode Setting, or Start Inhibit | View Details |
| – |
Interior light does not turn on when door is opened
|
Door Switch or LED Module Failure | View Details |
| – |
Water pooling inside the ice storage bin or at the bottom of the compartment
|
Internal Drainage or Meltwater Management Problem | View Details |
No matching codes found
Advertisements