SMEG Insufficient Water Fill or Short Freeze Cycle

Ice maker runs but produces very small or thin ice cubes.

Advertisements

Possible Causes

Partially clogged water inlet valve, Low household water pressure, Misadjusted water level sensor, Evaporator thermistor out of calibration

How to Fix / Troubleshooting

Safety first: Unplug the unit and close the water supply before disconnecting hoses.

Steps to improve cube size:

  • Check water pressure: Ensure the supply line delivers adequate pressure (typically 1–10 bar). If pressure is low, correct plumbing issues or use a larger supply line.
  • Clean inlet valve screen: Remove the supply hose and clean the mesh filter at the water inlet valve to restore full flow.
  • Inspect water level sensor: Some SMEG models use a float or probe in the sump. Clean mineral deposits from the sensor so it can accurately detect water level.
  • Run a descaling cycle: Mineral buildup on the evaporator plate can cause early ice release. Descale the system using SMEG-approved cleaner.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Inlet Valve
Check Price on Amazon

We may earn a commission from links on this page.