Vremi
Low Voltage to Control Panel
Display lights are dim, flicker, or go out intermittently while the unit is running.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failing internal power supply on control board, Loose display ribbon cable, Intermittent power cord connection, Overloaded outlet or extension cord
How to Fix / Troubleshooting
Safety: Unplug the ice maker before accessing the control panel.
Steps:
- 1. Plug directly into wall: Avoid using extension cords or power strips; plug the Vremi ice maker directly into a grounded wall outlet.
- 2. Check power cord: Wiggle the cord gently at the unit and outlet (with power off) to see if there is any looseness. Replace the power cord assembly if suspect.
- 3. Reseat display cable: Remove the top/front panel and reseat the ribbon cable between the display and main board.
- 4. Replace control board: If flickering persists and other components behave normally, the main control board may have a failing power supply and should be replaced.
Note: Persistent dimming can precede complete control failure; address early to avoid downtime.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Control Board