E1
Ice maker stops and displays E1 on the control panel; unit may still power on but will not start an ice-making cycle.
Ambient Temperature Sensor Failure
E10
E10 error displayed; unit may not fill with water or may stop shortly after starting.
Water Pump / Circulation Failure
E11
E11 error on display; unit may overfill or underfill the ice-making tray; ice size may be very inconsistent.
Water Fill Valve / Flow Sensor Fault
E12
E12 error displayed; unit may shut down shortly after starting; internal fan may not run.
Condenser Fan Motor Failure
E13
E13 error on display; unit may not detect when the ice basket is in place; cycles may not start.
Ice Basket Position Switch Fault
E14
E14 error displayed; unit may freeze water but fail to release ice cubes into the basket.
Harvest Motor / Ejector Mechanism Fault
E15
E15 error on display; unit may shut down and not respond until power is cycled.
Overcurrent / Internal Protection Trip
E2
E2 error on display; ice maker powers on but will not start or complete an ice cycle; fan may run intermittently.
Evaporator Temperature Sensor Failure
E3
E3 error displayed; ice maker may start but stops mid-cycle or fails to harvest ice properly.
Water Level Sensor / Float Switch Fault
E4
E4 error appears; unit may beep and stop; ice basket may be empty or partially full.
Ice Full Sensor / Infrared Beam Fault
E5
E5 error on display; compressor may not start or may shut down quickly; unit stops making ice.
Compressor Overload / High Temperature Protection
E6
E6 error displayed; unit may power on but no ice is produced; water pump and fan may still run.
Compressor Start Failure / PTC Relay Fault
E7
E7 error on display; unit may stop mid-cycle; ice size may be inconsistent before the error appears.
Ice Thickness Sensor / Probe Fault
E8
E8 error displayed; unit may fill with water but will not freeze properly; cycles may abort early.
Defrost / Evaporator Over-ice Protection Fault
E9
E9 error on display; unit may not respond to button presses or may behave erratically.
Control Panel / Keypad Communication Error
Symptom
Buttons on the control panel do not respond or respond only intermittently.
Keypad / Touch Button Failure
Symptom
Clicking sound from compressor area; compressor tries to start but shuts off repeatedly; little or no cooling.
Compressor Hard Start / Overload Cycling
Symptom
Display lights are dim, flicker, or go out intermittently while the unit is running.
Low Voltage to Control Panel
Symptom
High-pitched squealing or grinding noise from inside the unit during operation.
Worn Fan Motor or Pump Bearings
Symptom
Ice cubes are very small, thin, or hollow; ice basket fills with weak, quickly melting cubes.
Insufficient Water Fill / Premature Harvest
Symptom
Ice cubes stick to the evaporator and do not drop into the basket; ice builds up on the plate.
Harvest Failure Due to Scale or Temperature Imbalance
Symptom
Ice maker leaks water onto the counter or inside the cabinet; puddles form under or around the unit.
Water System Leak / Drain Misrouting
Symptom
Ice maker makes ice very slowly; production is much lower than normal and cubes may be small or hollow.
Poor Heat Exchange / Partial Refrigerant Restriction
Symptom
Ice maker powers on but will not start any cycle; all indicator lights may be on or flashing, but no sounds from inside.
Main Control Board Power Supply Failure
Symptom
Ice maker runs but makes no ice at all; fan and pump may run, but the evaporator plate never gets cold.
Refrigerant Loss / Sealed System Failure
Symptom
Loud rattling or vibrating noise during operation; unit may move slightly on the counter.
Cabinet Vibration / Loose Components
Symptom
Unit cycles on and off rapidly without completing a full ice-making cycle.
Control Logic Instability / Sensor Misread
Symptom
Unit does not power on at all; no lights, no sounds, completely dead.
Incoming Power / Line Fuse Failure
Symptom
Unit emits a burning smell or visible smoke during operation.
Electrical Overheating / Component Burnout
Symptom
Unit frequently indicates 'Ice Full' and stops even when the basket is not full (no specific code).
False Ice Full Detection
Symptom
Unit frequently shows 'Add Water' or stops due to low water even when the reservoir is full (no specific code).
False Low Water Detection
Symptom
Unit is excessively hot to the touch on the sides or top during normal operation.
Cabinet Heat Soak / Inadequate Ventilation
Symptom
Unit makes a gurgling or bubbling noise from inside the cabinet.
Normal Refrigerant Flow Sounds / Possible Low Charge
Symptom
Unit produces ice with a strong plastic, chemical, or musty odor or taste.
Contaminated Water Path / New Plastic Off-gassing
Symptom
Unit runs but the internal fan does not blow air; interior feels stagnant and ice production is reduced.
Internal Circulation Fan Failure
Symptom
Unit shuts off unexpectedly after running for a short time and will not restart until it cools down.
Thermal Overload / Overheating Protection
Symptom
Visible mold, slime, or discoloration inside the water reservoir or ice bin.
Microbial Contamination of Water System
Symptom
Water appears inside the ice storage bin under the ice, causing cubes to clump and melt quickly.
Poor Ice Bin Drainage / Ambient Heat Ingress