E3
Vremi Water Level Sensor / Float Switch Fault

E3 error displayed; ice maker may start but stops mid-cycle or fails to harvest ice properly.

Advertisements

Possible Causes

Stuck mechanical float, Faulty water level sensor switch, Mineral buildup on float mechanism, Disconnected or damaged float switch wiring

How to Fix / Troubleshooting

Safety: Unplug the ice maker and remove the water reservoir before working inside the unit.

How to troubleshoot:

  • 1. Remove and clean the reservoir: Take out the water tank and rinse thoroughly. Check for debris that could interfere with the float or sensor.
  • 2. Locate the float/sensor: In most Vremi countertop ice makers, the water level is detected by a float arm or a magnetic float in a tube near the reservoir or pump intake.
  • 3. Free a stuck float: Move the float up and down by hand. It should move smoothly. If it sticks, clean the area with warm water and a mild descaling solution to remove mineral deposits.
  • 4. Inspect wiring: Follow the float switch wires to the control board. Ensure the connector is fully seated and wires are not broken or pinched.
  • 5. Electrical test: With the unit unplugged, disconnect the float switch and test continuity with a multimeter while moving the float. The switch should open and close as the float moves. If it stays open or closed, the switch is defective.
  • 6. Replace faulty parts: Install a new Vremi water level float switch assembly if the switch fails testing or the float is damaged. Reassemble and test the unit.

Tip: Regular descaling of the water path helps prevent float sticking and E3 errors.