Ice maker runs but makes no ice at all; fan and pump may run, but the evaporator plate never gets cold.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Unplug the ice maker. Do not attempt to cut or open any refrigerant lines yourself.
Diagnostic steps:
- 1. Check evaporator temperature: After 10–15 minutes of operation, carefully touch the evaporator plate. It should be very cold. If it remains at room temperature, there is likely a sealed-system issue.
- 2. Listen to compressor: Confirm the compressor is running (steady hum and slight vibration). A running compressor with no cooling suggests low refrigerant or internal compressor failure.
- 3. Inspect for oil stains: Look around the evaporator and tubing for oily residue, which can indicate a refrigerant leak.
- 4. User-level options: There is no safe DIY repair for refrigerant leaks or compressor replacement on Vremi ice makers. These require specialized tools and EPA-certified technicians.
Action: Contact a professional appliance technician or Vremi support. In many cases, sealed-system failures on compact ice makers are not economical to repair and the unit may need replacement.