E7
Vremi
Ice Thickness Sensor / Probe Fault
E7 error on display; unit may stop mid-cycle; ice size may be inconsistent before the error appears.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Bent or misaligned ice thickness probe, Scale buildup on thickness sensor, Failed ice thickness thermistor, Loose sensor wiring to control board
How to Fix / Troubleshooting
Safety: Turn off and unplug the ice maker before reaching into the ice-making chamber.
Steps:
- 1. Locate the thickness sensor: On many Vremi models, a metal probe or sensor arm sits near the evaporator grid to detect ice thickness during harvest.
- 2. Inspect for damage: Check if the probe is bent, broken, or touching the evaporator incorrectly. Gently bend it back to the original position if misaligned.
- 3. Clean scale buildup: Mineral deposits can insulate the sensor. Use a soft cloth and a 1:1 mixture of white vinegar and water to clean the probe thoroughly. Rinse with clean water and dry.
- 4. Check wiring: Follow the sensor wires to the control board. Ensure the connector is fully seated and wires are intact.
- 5. Replace sensor if needed: If E7 persists after cleaning and alignment, replace the Vremi ice thickness sensor/probe assembly.
Note: After replacement, run several cycles to allow the control to recalibrate ice size.