Vremi Thermal Overload / Overheating Protection

Unit shuts off unexpectedly after running for a short time and will not restart until it cools down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked ventilation grills, Failed condenser fan, High ambient temperature, Faulty thermal cutoff on compressor

How to Fix / Troubleshooting

Safety: Unplug the unit and allow it to cool before further inspection.

Steps:

  • 1. Improve airflow: Move the ice maker to a well-ventilated area with adequate clearance on all sides.
  • 2. Clean vents and condenser: Remove dust from all air inlets and outlets and clean the condenser coils.
  • 3. Check fan operation: Ensure the condenser fan motor runs whenever the compressor is on. Replace if not.
  • 4. Thermal device: If the compressor shuts off prematurely and the overload protector is tripping, a technician should evaluate the compressor and overload device.

Note: Continuous overheating can permanently damage the compressor.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.