H1
Whynter
High Temperature Alarm / Inadequate Cooling
H1 or HI temperature warning, ice compartment too warm
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Door or lid not sealing, Dirty condenser coil, Failed condenser fan, Low refrigerant charge, Faulty temperature sensor
How to Fix / Troubleshooting
Safety: Unplug the unit before cleaning or accessing internal parts.
Steps to address H1:
- Check door/lid seal: Inspect the gasket for tears, warping, or debris. Clean the gasket with warm soapy water and ensure the door closes fully without obstruction.
- Verify ambient conditions: Ensure the unit is not installed in a very hot area and has proper ventilation clearance.
- Clean condenser: Remove the rear panel and clean the condenser coil with a brush and vacuum.
- Check condenser fan: Confirm the fan runs when the compressor is on. Replace the fan motor if it does not start or is noisy.
- Monitor temperature: Place a thermometer in the ice compartment and run the unit for several hours. If it does not reach the specified temperature, there may be a sealed system issue or sensor fault.
- Sensor check: Test the compartment temperature sensor as described for F1. Replace if readings are incorrect.
- Technician service: If airflow and sensors are good but cooling is still inadequate, a refrigerant leak or compressor problem is likely and requires professional repair.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements