E10
Bush
Door Latch / Door Sensing Error
Microwave shows E10 and beeps; door may appear closed but unit refuses to run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Bent door latch hooks, Worn door latch receiver on cabinet, Misaligned door hinges, Broken door spring or hinge components
How to Fix / Troubleshooting
Safety: Unplug the microwave before adjusting mechanical parts.
- Inspect door alignment: Check that the door sits squarely in the opening and that the gap is even all around. If the door sags, the hinges may be worn or loose.
- Check latch hooks: Open the door and inspect the plastic latch hooks at the top/side. If they are cracked, bent, or loose, they may not fully engage the interlock switches.
- Inspect latch receiver: Look inside the cabinet where the hooks enter. Ensure the latch bracket is not bent or loose. Tighten mounting screws if necessary.
- Test operation: After any adjustment, close the door firmly and try starting a short cycle. Do not bypass or tape down door switches; this is extremely dangerous.
- Replace worn parts: If hooks or hinges are damaged, replace the door latch assembly or hinge kit specific to your Bush model.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Door Latch Assembly