E7
Oster
Keypad matrix or touch panel failure
Microwave shows E7 and beeps; keypad may be unresponsive or partially responsive.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn membrane keypad, Moisture damage to keypad contacts, Cracked control panel PCB, Loose keypad ribbon connector
How to Fix / Troubleshooting
Safety first: Unplug the microwave before removing the control panel.
- Dry out moisture: If steam or liquid has recently contacted the control panel, unplug the unit and let it dry for several hours. Do not use a hair dryer or heat gun directly on the panel.
- Clean the surface: Wipe the keypad with a soft, slightly damp cloth and then dry thoroughly. Avoid harsh chemicals that can damage the membrane.
- Reseat keypad ribbon: Remove the control panel and carefully disconnect and reconnect the keypad ribbon cable to the main board. Ensure it is fully seated and not corroded.
- If certain keys never work: The membrane keypad is likely worn out. Replace the control panel/keypad assembly with the correct Oster part for your model.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Membrane Keypad
Check Price on Amazon