Oster
Cavity lamp failure
Microwave interior light does not come on when cooking or when door is opened, but unit heats normally.
Advertisements
Possible Causes
Burned-out cavity bulb, Loose lamp socket, Failed lamp relay on control board, Broken lamp wiring
How to Fix / Troubleshooting
Safety first: Unplug the microwave before replacing the bulb. Avoid touching the new bulb glass with bare fingers.
- Access lamp: On many Oster models, the lamp is accessible by removing the outer cabinet or a small lamp cover.
- Inspect bulb: Check if the filament is broken or the bulb is darkened. Replace with the correct wattage and type specified by Oster.
- Check socket: Ensure the bulb is seated firmly and the socket is not burned or loose.
- If new bulb does not work: The lamp relay or wiring may be faulty and will require control board or harness repair by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements