Oster Cavity lamp failure

Microwave interior light does not come on when cooking or when door is opened, but unit heats normally.

Advertisements

Possible Causes

Burned-out cavity bulb, Loose lamp socket, Failed lamp relay on control board, Broken lamp wiring

How to Fix / Troubleshooting

Safety first: Unplug the microwave before replacing the bulb. Avoid touching the new bulb glass with bare fingers.

  • Access lamp: On many Oster models, the lamp is accessible by removing the outer cabinet or a small lamp cover.
  • Inspect bulb: Check if the filament is broken or the bulb is darkened. Replace with the correct wattage and type specified by Oster.
  • Check socket: Ensure the bulb is seated firmly and the socket is not burned or loose.
  • If new bulb does not work: The lamp relay or wiring may be faulty and will require control board or harness repair by a technician.