E10
Severin
EEPROM / Control Board Memory Error
Microwave shows E10 and beeps continuously; no functions can be selected.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted firmware, Failed EEPROM chip, Power surge damage to control PCB, Poor solder joints on memory IC
How to Fix / Troubleshooting
Safety first: Unplug the microwave before opening the control panel.
- Step 1 – Power cycle: Disconnect from mains for at least 10 minutes to allow the control to fully reset. Plug back in and check if E10 clears.
- Step 2 – Surge protection: If the error followed a power outage or surge, connect the microwave via a surge-protected outlet to prevent recurrence.
- Step 3 – Inspect control PCB: Remove the control panel and visually inspect the board for burn marks, cracked solder joints, or damaged ICs. Lightly press on socketed components (if any) to ensure they are seated.
- Step 4 – Replace control board: In most cases, E10 requires replacement of the entire control PCB, as EEPROM reprogramming is not user-serviceable. Order the correct Severin control module by model number.
Advertisements
Repair Difficulty
Hard
4/5