E16
Severin Inverter Power Module Fault (for inverter-based models)

Microwave shows E16; fan and light may run but no heating occurs.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed inverter board, Loose inverter connectors, Overheated inverter module, Faulty magnetron current sensing

How to Fix / Troubleshooting

Safety first: Unplug the microwave. Inverter circuits operate at high voltage and high frequency; servicing should be done only by trained personnel.

  • Step 1 – Power reset: Disconnect for 10–15 minutes, then reconnect and test. Transient faults may clear.
  • Step 2 – Check cooling: Ensure vents are clear and the cooling fan is operating, as inverter modules are sensitive to overheating.
  • Step 3 – Visual inspection: With the cabinet removed, inspect the inverter board for burnt components or bulging capacitors. Do not touch the board while powered.
  • Step 4 – Professional replacement: If E16 persists, the inverter module or magnetron current sensing circuit likely needs replacement by a Severin service center.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Inverter Power Board
Check Price on Amazon