E17
Severin Monitor Switch / Safety Interlock Error

Microwave displays E17 and will not start; interior light may stay on with door closed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrectly adjusted monitor switch, Shorted monitor switch, Miswired door switch harness, Damaged switch bracket

How to Fix / Troubleshooting

Safety first: Unplug the microwave. The monitor switch is part of the safety system; incorrect repair can be hazardous.

  • Step 1 – Inspect door switches: Remove the cabinet and locate the three door switches (primary, secondary, monitor). Ensure they are firmly mounted and actuated in the correct sequence when the door opens/closes.
  • Step 2 – Check wiring order: Verify that wires are connected to the correct terminals as per the wiring diagram (often printed on the cabinet). Miswiring can trigger E17.
  • Step 3 – Test monitor switch: With a multimeter, confirm that the monitor switch is closed when the door is open and open when the door is closed (opposite of the primary switch). Replace if it does not operate correctly.
  • Step 4 – Replace damaged bracket: If the switch mounting bracket is bent or cracked, replace it to ensure proper alignment.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Monitor Door Switch
Check Price on Amazon

We may earn a commission from links on this page.